Products > CONTROL CABLES > > Control Cable with PVC Insulation and Sheath
Product name : Control Cable with PVC Insulation and Sheath
 Enlarge Image                   Back
←[Previous Product]              [Next Product]→


Details:

It is used for supervising and controlling return circuit and protective circuit of A.C rated voltage of 450/750V or lower.
Executive standard: GB9332-88

Type, Description and Application Occasion



Type

Description

 Application occasion

KVV

Control cable with Cu core, PVC insulation and sheath

To be fixedly laid indoor, in cable furrow, pipe

KVVP

Control cable with Cu core, PVC insulation and sheath, braided shielding

To be fixedly laid indoor, in cable furrow, pipe with demand on shielding

KVVP2

Control cable with Cu core, PVC insulation and sheath, copper tape shielding

To be fixedly laid indoor, in cable furrow, pipe with demand on shielding

KVV22

Control cable with Cu core, PVC insulation and sheath, steel tape armoring

To be fixedly laid indoor, in cable furrow, pipe, underground with demand on enduring strong mechanical force

KVV32

Control cable with Cu core, PVC insulation and sheath, steel wire armoring

To be fixedly laid indoor, in cable furrow, pipe, shaft with demand on enduring strong mechanical force

KVVR

Control soft cable with Cu core, PVC insulation and sheath

To be laid indoor with demand on mobility and softness.

KVVRP

Control soft cable with Cu core, PVC insulation and sheath, braiding shielding

To be laid indoor with demand on mobility and softness.

Note: we also produce flame retardant cable according to the requirements of customer. Prefix “ZR-” should be added. E.g.: ZR-KVV type

Various Specification Range



Type

Rated voltage V

Nominal cross section off conductor area mm2

0.5

0.75

1.0

1.5

2.5

4

6

10

Core number

KVV KVVP

450/750

-

2-61

2-14

2-10

KVVP2

 

4-61

4-14

4-10

KVV22

7-61

4-61

4-14

4-10

KVV32

10-61

7-61

4-14

4-10

KVVR

 

4-61

KVVRP

4-61

4-48

Note: Cores recommended: 2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52 or 61


Related Products :
CONTROL CABLE FR-XLPE Insulated Conductors, CPE Jacket, 600V
CONTROL CABLE FR-XLPE Insulated Conductors, CPE Jacket, 600V
CONTROL CABLE FR-XLPE Insulated Conductors, CU Shield, CPE Jacket, 600V
CONTROL CABLE FR-XLPE Insulated Conductors, CU Shield, CPE Jacket, 600V
CONTROL CABLE FR-XLPE Insulated Conductors, PVC Jacket, 600V
CONTROL CABLE FR-XLPE Insulated Conductors, PVC Jacket, 600V
Thermocouple Control Cable
Thermocouple Control Cable